Spectrograph & Monochromator
Omni-λ Series spectrometer list of the main models

Model#

Description

Omni-λ150 Series

150mm focal length monochromators, interchangeable dual grating turret, stepping motor scanning system with 32-bit DSP control, USB2.0 computer interfaces, plus scan control software for Windows.  (Gratings are required for operation.)

Omni-λ1509

One entrance and exit slits, and 180° optical path.

Omni-λ300 Series

300mm focal length monochromators and spectrographs, a triple grating turret, stepping motor scanning system with 32-bit DSP control, USB2.0 computer interfaces, plus scan control software for Windows.  (Gratings are required for operation.)

Omni-λ3005

One entrance and exit slits, 90° optical path.

Omni-λ3006

One entrance slit and standard multichannel detector adapter flange at 90° optical path.

Omni-λ3007

One entrance slit, two exit slits at 90° and 180° optical paths, and a motorized exit slit selection mirror.

Omni-λ3008

One entrance and exit slits at 180°optical path, motorized exit port selection mirror, and multichannel detector adapter flange on 90° optical path.

Omni-λ3009

One entrance and exit slits at 180° optical path.

Omni-λ3015

3005 with Gold Coating on all reflective optics

Omni-λ3016

3006 with Gold Coating on all reflective optics

Omni-λ3017

3007 with Gold Coating on all reflective optics

Omni-λ3018

3008 with Gold Coating on all reflective optics

Omni-λ3019

3009 with Gold Coating on all reflective optics

Omni-λ500 Series

500mm focal length monochromators and spectrographs, a triple grating turret, stepping motor scanning system with 32-bit DSP control, USB2.0 computer interfaces, plus scan control software for Windows.  (Gratings are required for operation.)

Omni-λ5005

One entrance and exit slits, 90° optical path.

Omni-λ5006

One entrance slit and standard multichannel detector adapter flange at 90° optical path.

Omni-λ5007

One entrance slit, two exit slits at 90° and 180° optical paths, and a motorized exit slit selection mirror.

Omni-λ5008

One entrance and exit slits at 180°optical path, motorized exit port selection mirror, and multichannel detector adapter flange on 90° optical path.

Omni-λ5009

One entrance and exit slits at 180° optical path.

Omni-λ5015

5005 with Gold Coating on all reflective optics

Omni-λ5016

5006 with Gold Coating on all reflective optics

Omni-λ5017

5007 with Gold Coating on all reflective optics

Omni-λ5018

5008 with Gold Coating on all reflective optics

Omni-λ5019

5009 with Gold Coating on all reflective optics

Omni-λ750 Series

750mm focal lengthmonochromators and spectrographs, a triple grating turret, stepping motor scanning system with 32-bit DSP control, USB2.0 computer interfaces, plus scan control software for Windows.  (Gratings are required for operation.)

Omni-λ7505

One entrance and exit slits, 90° optical path.

Omni-λ7506

One entrance slit and standard multichannel detector adapter flange at 90° optical path.

Omni-λ7507

One entrance slit, two exit slits at 90° and 180° optical paths, and a motorized exit slit selection mirror.

Omni-λ7508

One entrance and exit slits at 180°optical path, motorized exit port selection mirror, and multichannel detector adapter flange on 90° optical path.

Omni-λ7509

One entrance and exit slits at 180° optical path.

Omni-λ7515

7005 with Gold Coating on all reflective optics

Omni-λ7516

7006 with Gold Coating on all reflective optics

Omni-λ7517

7007 with Gold Coating on all reflective optics

Omni-λ7518

7008 with Gold Coating on all reflective optics